一、产品概述
IHG立式不锈钢管道泵性能好、可靠性高、寿命长、结构合理、 外形美观
二、用 途
IHG型立式单级单吸化工泵,供输送不含固体颗粒,具有腐蚀性,粘度类似于水的液体,适用于石油、化工、冶金、电力、造纸、食口制药等部门,使用温度为-20℃~+105℃。
型号意义:
不锈钢管道离心泵性能参数表
泵型号 | 流量 | 扬程 (m) |
效率 (%) |
转速 (r/min) |
电机功率 (kw) |
汽蚀佘量 (m) |
|
---|---|---|---|---|---|---|---|
(m 3 /h) | (l/s) | ||||||
15-80 | 1.5 | 0.42 | 8 | 34 | 2800 | 0.18 | 2.3 |
20-110 | 2.5 | 0.69 | 15 | 34 | 2800 | 0.37 | 2.3 |
20-160 | 2.5 | 0.69 | 32 | 25 | 2900 | 0.75 | 2.3 |
25-110 | 4 | 1.11 | 15 | 42 | 2900 | 0.55 | 2.3 |
25-125 | 4 | 1.11 | 20 | 36 | 2900 | 0.75 | 2.3 |
25-125A | 3.6 | 1.0 | 16 | 35 | 2900 | 0.55 | 2.3 |
25-160 | 4 | 1.11 | 32 | 32 | 2900 | 1.5 | 2.3 |
25-160A | 3.7 | 1.03 | 28 | 31 | 2900 | 1.1 | 2.3 |
32-125 | 5 | 1.39 | 20 | 44 | 2900 | 0.75 | 2.3 |
32-125A | 4.5 | 1.25 | 16 | 43 | 2900 | 0.5 | 2.3 |
40-100 | 6.3 | 1.75 | 12.5 | 54 | 2900 | 0.55 | 2.3 |
40-100A | 5.6 | 1.56 | 10 | 52 | 2900 | 0.37 | 2.3 |
40-125 | 6.3 | 1.75 | 20 | 46 | 2900 | 1.1 | 2.3 |
40-125A | 5.6 | 1.56 | 16 | 45 | 2900 | 0.75 | 2.3 |
40-160 | 6.3 | 1.75 | 32 | 40 | 2900 | 2.2 | 2.3 |
40-160A | 5.9 | 1.64 | 28 | 39 | 2900 | 1.5 | 2.3 |
40-160B | 5.5 | 1.53 | 24 | 38 | 2900 | 1.1 | 2.3 |
40-200 | 6.3 | 1.75 | 50 | 33 | 2900 | 4.0 | 2.3 |
40-200A | 5.9 | 1.64 | 44 | 31 | 2900 | 3.0 | 2.3 |
40-200B | 5.3 | 1.47 | 36 | 29 | 2900 | 2.2 | 2.3 |
40-250 | 6.3 | 1.75 | 80 | 28 | 2900 | 7.5 | 2.3 |
40-250A | 5.9 | 1.64 | 70 | 28 | 2900 | 5.5 | 2.3 |
40-250B | 5.5 | 1.53 | 60 | 27 | 2900 | 4.0 | 2.3 |
40-100(I) | 12.5 | 3.47 | 12.5 | 62 | 2900 | 1.1 | 2.3 |
40-100(I)A | 11 | 3.05 | 10 | 60 | 2900 | 0.75 | 2.3 |
40-125(I) | 12.5 | 3.47 | 20 | 58 | 2900 | 1.5 | 2.3 |
40-125(I)A | 11 | 3.05 | 16 | 57 | 2900 | 1.1 | 2.3 |
40-160(I) | 12.5 | 3.47 | 32 | 52 | 2900 | 3.0 | 2.3 |
40-160(I)A | 11.7 | 3.25 | 28 | 51 | 2900 | 2.2 | 2.3 |
40-160(I)B | 10.4 | 2.89 | 22 | 50 | 2900 | 1.5 | 2.3 |
40-200(I) | 12.5 | 3.47 | 50 | 46 | 2800 | 5.5 | 2.3 |
40-200(I)A | 11.7 | 3.25 | 44 | 45 | 2900 | 4.0 | 2.3 |
40-200(I)B | 10.6 | 2.94 | 36 | 44 | 2900 | 3 | 2.3 |
40-250(I) | 12.5 | 3.47 | 80 | 38 | 2900 | 11 | 2.3 |
40-250(I)A | 11.6 | 3.22 | 70 | 38 | 2900 | 7.5 | 2.3 |
40-250(I)B | 10.8 | 3.0 | 60 | 37 | 2900 | 7.5 | 2.3 |
40-250(I)C | 10.0 | 2.78 | 52 | 36 | 2900 | 5.5 | 2.3 |
50-100 | 12.5 | 3.47 | 12.5 | 62 | 2900 | 1.1 | 2.3 |
50-100A | 11 | 3.05 | 10 | 60 | 2900 | 0.75 | 2.3 |
50-125 | 12.5 | 3.47 | 20 | 58 | 2900 | 1.5 | 2.3 |
50-125A | 11 | 3.05 | 16 | 57 | 2900 | 1.1 | 2.3 |
50-160 | 12.5 | 3.47 | 32 | 52 | 2900 | 3.0 | 2.3 |
50-160A | 11.7 | 3.25 | 28 | 51 | 2900 | 2.2 | 2.3 |
50-160B | 10.4 | 2.89 | 22 | 50 | 2900 | 1.5 | 2.3 |
50-200 | 12.5 | 3.47 | 50 | 46 | 2900 | 5.5 | 2.3 |
50-200A | 11.7 | 3.25 | 44 | 45 | 2900 | 4.0 | 2.3 |
50-200B | 10.6 | 2.94 | 36 | 44 | 2900 | 3 | 2.3 |
50-250 | 12.5 | 3.47 | 80 | 38 | 2900 | 11 | 2.3 |
50-250A | 11.6 | 3.22 | 70 | 38 | 2900 | 7.5 | 2.3 |
50-250B | 10.8 | 3.0 | 60 | 37 | 2900 | 7.5 | 2.3 |
50-250C | 10.0 | 2.78 | 52 | 36 | 2900 | 5.5 | 2.3 |
50-100(I) | 25 | 6.94 | 12.5 | 69 | 2900 | 1.5 | 2.5 |
50-100(I)A | 22.3 | 6.19 | 10 | 67 | 2900 | 1.1 | 2.5 |
50-125(I) | 25 | 6.94 | 20 | 68 | 2900 | 3.0 | 2.5 |
50-125(I)A | 22.3 | 6.19 | 16 | 66 | 2900 | 2.2 | 2.5 |
50-160(I) | 25 | 6.94 | 32 | 63 | 2900 | 4.0 | 2.5 |
50-160(I)A | 23.4 | 6.5 | 28 | 62 | 2900 | 4.0 | 2.5 |
50-160(I)B | 21.6 | 6.0 | 24 | 58 | 2900 | 3.0 | 2.5 |
50-200(I) | 25 | 6.94 | 50 | 58 | 2900 | 7.5 | 2.5 |
50-200(I)A | 23.5 | 6.53 | 44 | 57 | 2900 | 7.5 | 2.5 |
50-200(I)B | 21.8 | 6.06 | 38 | 55 | 2900 | 5.5 | 2.5 |
50-250(I) | 25 | 6.94 | 80 | 50 | 2900 | 15 | 2.5 |
50-250(I)A | 23.4 | 6.5 | 70 | 50 | 2900 | 11 | 2.5 |
50-250(I)B | 21.6 | 6.0 | 60 | 49 | 2900 | 11 | 2.5 |
50-315(I) | 25 | 6.94 | 125 | 40 | 2900 | 30 | 2.5 |
50-315(I)A | 23.7 | 6.58 | 113 | 40 | 2900 | 22 | 2.5 |
50-315(I)B | 22.5 | 6.25 | 101 | 39 | 2900 | 18.5 | 2.5 |
50-315(I)C | 20.6 | 5.72 | 85 | 38 | 2900 | 15 | 2.5 |
故障原因 | 排除方法 | |
1、水泵不出水 | a、进出口阀门未打开,进出管路堵塞,流道叶轮堵塞; | a、检查,去除堵塞物; |
b、电机运行方向不对,电机缺相转速很慢; | b、调整电机方向,紧固电机接线。 | |
c、吸入管漏气; | c、拧紧各密封面,排除漏气; | |
d、泵没灌满液体,泵腔内有空气; | d、灌满液体并打开排气阀,排尽空气; | |
e、进口供水不足,吸程过高,底阀漏水; | e、停机,检查、调整(并网自来水管或带吸程使用易出现此现象); | |
f、管路阻力过大,泵选型不当。 | f、减少管路弯道,重新选泵。 | |
2、水泵流量不足 | a、先按1.原因检查; | a、先按1.排除。 |
b、管道、泵流道叶轮部分堵塞,水垢陈积,阀门开度不足; | b、去除堵塞物,重新调整阀门开度; | |
c、电压偏低; | c、稳压; | |
d、叶轮磨损。 | d、更换叶轮; | |
3、功率过大 | a、超过额定流量使用; | a、调节流量,关小出口阀门; |
b、吸程过高; | b、降低; | |
c、泵轴承磨损; | c、更换轴承; | |
4、杂音振动 | a、管路支撑不稳; | a、稳固管路; |
b、液体混有气体; | b、提高吸入压力排气; | |
c、产生汽蚀; | c、降低真空度; | |
d、轴承损坏; | d、更换轴承; | |
e、电机超载发热运行。 | e、调整按5; | |
5、电机发热 | a、流量过大,超载运行; | a、关小出口阀; |
b、碰擦; | b、检查排除; | |
c、电机轴承损坏; | c、更换轴承; | |
d、电压不足; | d、稳压; | |
6、水泵漏水 | a、机械密封磨损; | a、更换; |
b、泵体有砂孔或破裂; | b、焊补或更换; | |
c、密封面不平整; | c、修整; | |
d、安装螺栓松懈; | d、紧固; |